CE Approval Universal Optical Tool Microscope Price

Usage: Research
Principle: Optics
Principle of Optics: Differential Interference Contrast Microscope
Product Name: Universal Tool Microscope
X-Y-Coordinate Measuring Range: 200×100mm
Division Value: 0.0005mm
Collimation Microscope Lifting Distance: 120mm
Clinometer Eyepiece Angle Measuring Range: 360°
Angle Measuring Range: ±7°
Curvature Radius: R0.1~100mm
Common Screw Distance: T = 0.25 - 6mm
Diameter of Glass Table: 106mm
Measuring Force: 8 - 14G
Trademark: NANBEI
Transport Package: 1 Set
Specification: ISO, CE
Origin: Henan, China(Mainland)
HS Code: 8486402900
Model NO.: 19JPC
Usage: Research
Principle: Optics
Principle of Optics: Differential Interference Contrast Microscope
Product Name: Universal Tool Microscope
X-Y-Coordinate Measuring Range: 200×100mm
Division Value: 0.0005mm
Collimation Microscope Lifting Distance: 120mm
Clinometer Eyepiece Angle Measuring Range: 360°
Angle Measuring Range: ±7°
Curvature Radius: R0.1~100mm
Common Screw Distance: T = 0.25 - 6mm
Diameter of Glass Table: 106mm
Measuring Force: 8 - 14G
Trademark: NANBEI
Transport Package: 1 Set
Specification: ISO, CE
Origin: Henan, China(Mainland)
HS Code: 8486402900
Main Technical Specification of All-Purpose Tool Microscope
 
Measuring Range and Division Value:
X-Y-coordinate Measuring range: 200×100mm; Division value: 0.0005mm

Collimation microscope lifting distance: 120mm

Arm of force inclining range: both 15° left and right; Division value: 10′

Lumination grating adjusting range: φ3~φ32mm; Division value: 1mm

Clinometer eyepiece angle measuring range: 360°; Division value: 1′

Figure eyepiece angle measuring range: ±7°; Division value: 10′

Circulate arc reticle curvature radius: R0.1~100mm

Screw reticle common screw distance t = 0.25 - 6mm

Trapezia screw distance T = 2 - 20mm

Optical indexing table Measuring range: 360°; Division value: 10″ (projected value)
(Optional) Diameter of glass table φ106mm

Optical dividing head Measuring range: 360°; Division value: 1′

Optical localizer Diameter of measuring head φ3±0.1mm; (Actual high-point diameter error can not more than 0.5μm.)

Measuring force: 8 - 14g

Max. measuring depth: 15mm

Glass worktable Glass worktable dimension: 215×130mm

Thimble bracket Max. clamping diameter: φ100mm
Max. clamping length: diameter of tested part ≤ 55mm, 750mm
                               diameter of tested part > 55mm, 600mm

High thimble bracket Max. clamping diameter: φ180mm
                                    Max. clamping length: 600mm

V-type bracket: Left V-type bracket front and behind adjusting range: both 5mm front and behind.
Right V-type bracket upper and downward adjusting range: upper 15mm; downward 3mm

Max. carrying capacity: 40kg

Optical Parameter of Collimation Microscope

Tag value of objective's zoom multiple

1×

3×

5×

Total zoom multiple

Clinometer or figure eyepiece

10×

30×

50×

Double-image eyepiece

15×

42×

65×

 
Field of view

Clinometer or figure eyepiece

φ20

φ6.6

φ4

Double-image eyepiece

φ13

φ4.7

φ3

Working distance

Clinometer or figure eyepiece

81

90

65

Double-image eyepiece

47

85

63

Optical Objective of Image Measuring Groupware
 

Zoom multiple

Total zoom multiple

Field of view

Working distance

3×

25×

Φ6

110

5×

37×

Φ4

95
 
Instrument Precision:
 Temperature requirement
(1) Workroom temperature should be 20 ± 2 °C.
(2) Workroom temperature change can not exceed 1 °C per hour.
(3) Tested part and instrument temperature difference can not exceed 0.5 °C.
In the condition of meeting all temperature requirement, the instrument has the following guarantee:
(1) X-Y-coordination When using glass millimeter ruler to examine, the Max. un-precision of the instrument is;
     0-level: (1 + L / 100)μm L: measuring length Unit: mm
     When the ruler corrects according to correction table, X-direction can not be more than 0.0035mm.
Y-direction can not be more than 0.0025.
(2) Clinometer eyepiece: Max. un-precision: not more than 1′.
(3) Double-image eyepiece: Instability of imaging: not more than 0.0005mm
                            Incorrectness of imaging: not more than 0.001mm.
(4) Optical dividing head: Max. un-precision: not more than 1′.
(5) Optical indexing table: Max. un-precision: not more than 30″(optional).
(6) Optical graduator: Instability of measuring: not more than 0.001mm.
                      Incorrectness of measuring: not more than 0.0015mm.
 CE Approval Universal Optical Tool Microscope Price

 
Packaging & Shipping
 Package : Standard export Wooden case package
Shipping : 3-10days after payment received