Fluorescence Spectrophotometer / Spectrofluorometer, ± 2.0nm, 12nm

Model NO.: SP-F95S
Certification: RoHS, ISO9001, CE
Customized: Customized
Detection Sensitivity: Quinine Sulfate Solution Detection Limit: 5 X 10-1
Excitation Wavelength Bandwidth: 10/20nm
Emission Wavelength Bandwidth: 12nm
Emission Wavelength Accuracy: ±2.0nm
Emission Wavelength Repeatability: ≤1.0nm
Light Source: High Intensity LED Cold Light Source
Trademark: Xiangyi
Transport Package: Carton/Plywood
Specification: 360× 320× 205mm
Origin: China
HS Code: 9027300000
Model NO.: SP-F95S
Certification: RoHS, ISO9001, CE
Customized: Customized
Detection Sensitivity: Quinine Sulfate Solution Detection Limit: 5 X 10-1
Excitation Wavelength Bandwidth: 10/20nm
Emission Wavelength Bandwidth: 12nm
Emission Wavelength Accuracy: ±2.0nm
Emission Wavelength Repeatability: ≤1.0nm
Light Source: High Intensity LED Cold Light Source
Trademark: Xiangyi
Transport Package: Carton/Plywood
Specification: 360× 320× 205mm
Origin: China
HS Code: 9027300000
  1. fluorescence intensity measurements and calculated sample concentrations, single sample fluorescence can be carried out quantitative and qualitative analysis.
  2. 128 * 64 LCD display, more user-friendly interface.
  3. cold light source with high reliability, relative to the heat source usually has a low background, low power, low temperature, long life, high strength advantage, avoid thermal pollution, more energy-saving advantages. 365nm excitation wavelength, quinine sulfate detection limit to 5 *10-10
  4. can be an external serial printer performs data printout, convenient data storage.
  5. supports stand-alone, on-line two modes, use the standalone state machine computer systems to provide fluorescence intensity measurements, establish the standard curve equation and preservation, concentration measurement, data printing, auto-zero, automatic background subtraction and other functions. Online and with selected general data processing software package for on-line operation, more convenient for you to further calculations and data processing, saving you hours of operation.
  6. variety of measurement accessories, including single-hole sample cell holder, multi-fluorescent sample holder, 200μL microcentrifuge tube measurement accessories, capillary micro sample measurement accessories, semi-automatic sample injection fluorescence attachment hole sample cell adapter, film and powder samples shaped sample measurement accessories and sheathed sample cell holder and so on. Wealth of accessories greatly expands the application range of the instrument.
  7. small size of the model can save a lot of desk space

Specifications:
Model SP-F95S
Detection sensitivity  Quinine sulfate solution detection limit: 5 x 10-10
Excitation wavelength Bandwidth 10/20nm
Emission wavelength Bandwidth 12nm
Emission Wavelength accuracy ±2.0nm
Emission Wavelength repeatability ≤1.0nm
Light source High intensity LED cold light source
Optical system C-T manually grating monochromator
Fluorescence Receiver Original photomultiplier (Hamamatsu, Japan)
Central wavelength 365nm (SP-F93)
365nm,405nm,470nm,515nm (SP-F93A)
Excitation wavelength range  250nm ~ 600nm, can be extended to 250-850 nm
Excitation wavelength 365nm/405nm/470nm/515nm
Emission wavelength range  200nm ~ 650nm, can be extended to 200-900nm
Measurement line ≥0.995
Gain adjustment range  0~7 position optional
Data transmission  RS232
Light value range 0.00-250
Peak intensity Repeatability  ≤1.5%
Power source  220V / 50Hz, 110V / 60Hz
Standard energy consumption  35W
Dimensions (mm)  360×320×205
Weight  7kg/9kg

Fluorescence Spectrophotometer / Spectrofluorometer, ± 2.0nm, 12nm
 
  1. fluorescence intensity measurements and calculated sample concentrations, single sample fluorescence can be carried out quantitative and qualitative analysis.
  2. 128 * 64 LCD display, more user-friendly interface.
  3. cold light source with high reliability, relative to the heat source usually has a low background, low power, low temperature, long life, high strength advantage, avoid thermal pollution, more energy-saving advantages. 365nm excitation wavelength, quinine sulfate detection limit to 5 *10-10
  4. can be an external serial printer performs data printout, convenient data storage.
  5. supports stand-alone, on-line two modes, use the standalone state machine computer systems to provide fluorescence intensity measurements, establish the standard curve equation and preservation, concentration measurement, data printing, auto-zero, automatic background subtraction and other functions. Online and with selected general data processing software package for on-line operation, more convenient for you to further calculations and data processing, saving you hours of operation.
  6. variety of measurement accessories, including single-hole sample cell holder, multi-fluorescent sample holder, 200μL microcentrifuge tube measurement accessories, capillary micro sample measurement accessories, semi-automatic sample injection fluorescence attachment hole sample cell adapter, film and powder samples shaped sample measurement accessories and sheathed sample cell holder and so on. Wealth of accessories greatly expands the application range of the instrument.
  7. small size of the model can save a lot of desk space

Specifications:
Model SP-F95S
Detection sensitivity  Quinine sulfate solution detection limit: 5 x 10-10
Excitation wavelength Bandwidth 10/20nm
Emission wavelength Bandwidth 12nm
Emission Wavelength accuracy ±2.0nm
Emission Wavelength repeatability ≤1.0nm
Light source High intensity LED cold light source
Optical system C-T manually grating monochromator
Fluorescence Receiver Original photomultiplier (Hamamatsu, Japan)
Central wavelength 365nm (SP-F93)
365nm,405nm,470nm,515nm (SP-F93A)
Excitation wavelength range  250nm ~ 600nm, can be extended to 250-850 nm
Excitation wavelength 365nm/405nm/470nm/515nm
Emission wavelength range  200nm ~ 650nm, can be extended to 200-900nm
Measurement line ≥0.995
Gain adjustment range  0~7 position optional
Data transmission  RS232
Light value range 0.00-250
Peak intensity Repeatability  ≤1.5%
Power source  220V / 50Hz, 110V / 60Hz
Standard energy consumption  35W
Dimensions (mm)  360×320×205
Weight  7kg/9kg

Fluorescence Spectrophotometer / Spectrofluorometer, ± 2.0nm, 12nm
 

Metal Base Plate

Metal Base Plate,Metal Terminal Box,Sheet Metal Base Plate,Oem Sheet Metal Baseplate

FCX Metal Structure Co., Ltd. , https://www.fcxmetal.com